PRODUCT: PowerFlex, FusionLug and Custom Injection Molding
 
CUSTOMER END PRODUCT: High-end mainframe data storage system
 
APPLICATION PROBLEM: Customer required 60 amp, 5 volt flexible jumper between back plane and power distribution pcb. Layout on both boards could not be changed so the solution needed to match existing power pads on both pcb’s----both were different sizes. Connector interface needed to be secured to each board and the entire assembly needed to be fully insulated for safety and hazard issues. Captive hardware preferred.
 
CABLECO SOLUTION: Custom FusionLugs were designed to match existing power pads on the back plane and power distribution pcb terminated on 6 awg PowerFlex wire for high flexibility. To secure the connection to the back plane, custom jackscrews were mounted to one FusionLug so it could be screwed down in to threaded PEM inserts mounted in the backplane. PEM threaded inserts were pressed in to the other FusionLug allowing mounting screws to come through the bottom of the power distribution pcb, in to the FusionLug to secure it to the power distribution pcb. Custom injection molded boots were designed for each FusionLug to insulate the entire assembly. The jackscrews were held in place by the boot eliminating loose hardware----making it a captive hardware, highly flexible, completely insulated solution.


Download PDF